English

русский

español

中文

Home > Air Heat Exchanger > Counter Flow Heat Exchanger >ERV/HRV Ventilator Air to air exchanger

Products

ERV/HRV Ventilator Air to air exchanger

  • AIR-ERV
  • 1

Details

We supply ERV/HRV Ventilator Air to air exchanger.

Product Description

Are you finding a ERV/HRV Ventilator Air to air exchanger?

Look at our counterflow air to air heat exchanger to see what features and advantages we have

-made of anti-corrosive hydrophilic aluminum foil and galvanized sheet framework,with long service life.

-Five layer curring,corrugated undercut,the air tightness up to 99.9%.

-Counterflow,two airstreams never come into direct contact,avoid any transfer of smell and moistrure.

-No running parts,with strong reliability

-Can be directly clean with water or neutral detergent, easy to use and simple maintenance.

 Air to air exchangers

************************************************************************************************************

If you are insteresting in our ERV/HRV Ventilator Air to air exchanger,click here to contact with Jenny Yang.

************************************************************************************************************

 Air to air exchangers

Counterflow air to air heat exchanger Working principle:

The ERB is Counter flow and sensible heat exchanger. Two air streams are passed though the separate air channel and exchanged the energy. This design not only improves the heat transfer area, but also the energy efficient.

 Air to air exchangers

************************************************************************************************************

If you are insteresting in our Counterflow air to air heat exchanger,click here to contact with Jenny Yang.

************************************************************************************************************

Production technology

1.?The face of Counterflow plate heat exchanger process with strengthened heat transfer stamping, increased the 10% heat transfer area.

2. Adopt stamping convex round as air passage support, guarantee the high strength and tightness of Channel, high fresh air and exhaust air bearing capability.

3. Cross channel between ourdoor air and exhaust air, separate by aluminium foil,entry edge and exit edge process with five layer crimping techniques,have higher edge intensity and more reliable seal.

4. All joints are airproofed by airproof glue, ensure that theheat exchanger has excellent air tightness.

Remark: Corrugated air channel available for application,which process by spot-face airtight technology,solved the penetration and pollution problem which exist in spot-spot technology,completely stop exhaust air pollute outdoor air.

?

Model range

?Air to air exchangers


1. When selection,we suggest you select economic wind speed (1m/s~2.5m/s) as far as possible,so as to achieve good and economic operating effect.

2.The core size and plate distance can be produce on request.

ERB Applied range:

The ERB air to air heat exchanger core is the major part of cabinet or base station ventilation, for air volumes up to 5000 m3/h,The heat exchanger controlled the ventilation, recover the heat energy in winter and cold energy in summer, not only save the energy but also give station for fresh air, ensure the normal 

 Air to air exchangers

Packaging & Shipping

We care about all the details in the product process.

♦ Packing
1. Dust Proof Film + Anti-collision Foam + 5 Layer Cartons + Ply-wooded Case (For LCL only, no need fumigation).
2. Customized packing is available.
3. We are always working hard on the most reliable packing in order to help you get the Perfect products.

As Heat Recovery Ventilation Unit has the soft character to cause the easy deformation, we focus on the safe packing in different transportation way.

Full container:PVC bag + strong carton (pallet for option)

LCL:PVC bag + special strong carton + pallet

By air / courier:PVC bag + carboard inserted in carton + special strong carton

 

 Air to air exchangers

************************************************************************************************************

If you are insteresting in our plate heat exchanger,click here to contact with Jenny Yang.

************************************************************************************************************

Company Information

AIRERV Factory

AIRERV  is one of the best manufacturer in ERV/HRV, heat exchanger and AHU area in China, founded in 1996, areas covered more than 30,000 square meters, turnover of 2012 is 42 million dollars, we have enthalpy testing lab. for products test. As a leader in energy/heat recovery equipments, we cooperate with more than 30 famous companies who located in Europe, the Middle east, Korea, Southeast Asia, Taiwan, etc. supplied equipment to Beijing Olympic and Shanghai Expo 2010, works together with domestic and international brands like Midea, Daikin,Shenling, etc.

Air to air exchangersAir to air exchangers

AIRERV partner

AIR-ERV cooperate with world famous brand or offer OEM service including Midea,Shenling,Daikin, etc.

 

AIRERV certificate

AIR-ERV products stand for TOP quality in heat recovery ventilation filed in China, certificated by CE, Eurovent, ISO and other different approved tests like anti-flaming test, anti-mold test, energy saving product test. Etc.

Air to air exchangersAir to air exchangersAir to air exchangersAir to air exchangers

Our Services

1. AIR-ERV can supply OEM service for customers.

2. Produce ERV/HRV, heat exchanger according to customer's special demands.

3. Supply spare parts according to order quantity.

4. General testing and operational test carried out for every units before delivery.

5. Long warranty period.

FAQ

What's the difference between sensible heat exchanger and total heat exchanger?
1.Sensible heat exchanger is made of Aluminium foil,total heat exchanger is made of paper.
2.Sensible heat exchanger only exchange heat,total heat exchanger can exchange both heat and humidity.
3.Sensible heat exchanger has longer life and higher pressure-resistance than total total exchanger.
   Because the paper heat exchanger are easy to be corroded by the water and dust in the air.The vent of 
   total heat exchanger is easy to be blocked and hard to be cleaned.This will lead to bad ventilated effect.

Welcome to our ERV/HRV Ventilator Air to air exchangers.

Previous :total air to air ER paper crossflow heat core

Next :ERB counterflow air to air heat exchanger

XIAMEN AIR-ERV Technology Co., Ltd

Tel: +86-86-592-5769019
Fax:+86-0592-7155233

Contact Person: Jeffrey
Mobile:+86-15105979197

Website:www.airerv.com


Send your inquiry directly to us Email:

(0 / 3000)

Related Products+More

jeffrey0748