Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

abide by the contract", conforms on the market requirement, joins from the market competition by its good quality likewise as provides more comprehensive and superb support for customers to let them become large winner. The pursue of the company, is definitely the clients' pleasure for Heat And Ventilation, Heat Recovery Ventilator Malaysia, Air Ventilation Design, We encourage you to make get hold of as we've been wanting for companions inside our venture. We are sure you'll uncover doing company with us not only fruitful but also profitable. We've been prepared to provide you with what you require.
Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV Detail:

ERD Cross&Counter Flow Heat exchanger Core
Cross & counter flow heat exchanger core is made of antiseptic hydrophilic/aluminum foil and galvanized sheet cover.A part of air is cross flow, and the other is counter flow, combined the working methods both cross flow and counter flow heat exchanger core, achieve more higher heat efficiency.
It is usually being used for recovering energy at residential household, commercial and industrial ventilation systems.

1 2

Feature:
1.Adopt antiseptic hydrophilic aluminium, resistant to corrosion, with long service life.
2.Module and compact structure, no use of rivets or screws.
3.No running components, low maintenance cost.
4.Suitable for washing with water or neutral detergent.
5. Extremely high strength and pressure related stability.

Production Technology:
1.The surface of heat exchanger core was processed with heat transfer enhancement techniques, increased the 10% heat transfer area.
2.Convex and concave air channel, ensure the strength and tightness of heat exchanger core, could bear high pressure.
3.Counter air channel, double folding process of the face side edges, which is equal to 5 times material thickness, ensure the high intensity and tightness.
4. All joints are airproofed by airproof glue, ensured that the heat exchanger core has excellent air tightness.

3

Model Range:

126

Application:
The cross flow and counter flow heat exchanger core is the major part of heat recovery ventilator(HRV).The heat exchanger core work for ventilation, recover the heat energy in winter and cold energy in summer, not only save the energy but also give room for fresh air.

Combination:

212121

Package and Delivery:
Packaging Details: carton or plywood case.
Port: Xiamen port, or as requirement.
Transport Way: by sea, air, train, truck, express etc.
Delivery Time: as below.

  Samples Mass production
Products Ready: 7-15 days To be negotiated

0180128


Product detail pictures:

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures


Related Product Guide:

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV , The product will supply to all over the world, such as: Korea, Greek, Malawi, Due to the stability of our products, timely supply and our sincere service, we are able to sell our products not only over the domestic market, but also exported to countries and regions, including the Middle East, Asia, Europe and other countries and regions. At the same time, we also undertake OEM and ODM orders. We will do our best to serve your company, and establish a successful and friendly cooperation with you.
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Marguerite from Indonesia - 2018.06.19 10:42
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Althea from Singapore - 2017.03.28 12:22
    Write your message here and send it to us